Links for this product
Support for this product
Software and application
Info about selling this product
View Technical specification
This line of data cables is designed for analog and digital signal transmission in audio, video and data applications in data communications systems supporting 100 MHz, 1.0 Gbit/s 1 Gigabit Ethernet. The cables meet the requirements of structural cabling standards including ANSI EIA/TIA 568, ISO/IEC 11801 and EN 50173 Class D. IEEE 802.3:10Base-T; 100Base-T; 1000Base-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM Power over Ethernet (PoE) / PoE+
Design: PVC
Packing: 300m
- Conductor Electrolytic copper wire, Ø 24AWG
- Insulation HDPE, in compliance with TIA 568 insulation colour coding 80°C, EN 50290-2-23
- Sheath LSZH/LS0H – RAL 1015 Cream, Ø 5.0 mm 70°C, EN 50290-2-27 PVC – RAL 7001 Grey, Ø 5.0 mm TM51 70°C, EN 50290-2-22 PE – RAL 9011 Black, Ø 5.0 mm 80°C, EN 50290-2-24
Temperature range | fixed -20°C …+60°C flexing 0°C …+50°C |
Bending radius min. Tensile strength Crushing strength Impact strength | fixed min. 4 x D flexing min. 8 x D max. 85 N min. 1000 N/10 cm min. 10 impacts |
Resistance imbalance | max. 2% |
Conductor resistance | max. 95 ?/km |
Insulation resistance Capacitance Capacity imbalance Rated impedance Velocity of propagation Propagation delay Signal delay | min. 5000 M? x m nom. 50 pF/m 1600 pF/km 100 ± 5 ? @100 MHz 67-69% 537 ns/100 m max. 45 ns/100 m |
Test voltage | 1000 V |
Operating voltage max. TCL Coupling attenuation Segregation class | Max 72 V “Level 2” “Type III” “b” EN 50174-2 |
Standards | ISO/IEC 11801 2nd ed., IEC 61156-5 EN 50173-1, EN 50288-3-1 ANSI EIA/TIA 568-C.2 |
Fire performance | Vertical flame propagation EN 60332-1-2 (LSZH-PVC) Corrosive gas EN 60754-1/2 (LSZH) Smoke density EN 61034-2 (LSZH) |
EU declaration of conformity | LVD Low Voltage Directive 2014/35/EU RoHS Restriction of Hazardous Substances 2011/65/EU |